Maintenance
15
AJ1032
Cleaning Air Filter
Air filter removes foreign matter and condensate from 
supply air as it passes through filter. Frequency at 
which the filter baffle plate and filter element should 
be cleaned depends upon amount of condensate and 
foreign matter in supply air. Condensate level should 
not rise above baffle. This is the sign of a faulty auto-
drain which would need to be cleaned, replaced or 
repaired.
Erratic regulator operation or loss of regulation is 
almost always due to dirt.
The following steps outline the procedure for cleaning 
air filter.
1. Close and lock air supply line shut-off valve.
2. Remove filter bowl. Use a strap wrench if
required. Disassemble regulator, making notes as 
a guide for reassembly.
3. Clean parts with household soap (Dawn™,
Ivory™, etc.) and blow out body with 
compressed air.
NOTE: DO NOT use cleansing agents such as 
acetone, benzene, carbon tetrachloride, gasoline, or 
toluene, which are damaging to plastic sight glass.
4. Reassemble per notes from step 2. Ensure o-ring
is in position on filter bowl. Tighten bowl to filter 
body. Tighten slightly more than hand tight.
5. Open air service shut-off valve.
6. Check for leaks and adjust as necessary.
Cleaning Steam Strainer
Strainer removes foreign matter from steam. 
Frequency at which strainer must be cleaned is 
dependent upon amount of foreign matter suspended 
in steam. Removing and checking strainer screen for 
cleanliness after two weeks or after 80 hours of 
operation is recommended. If little or no foreign 
matter has collected on screen, time between 
inspections can be increased accordingly.
Cleaning Customer-Furnished Steam 
Traps
Some steam traps are provided with internal steam 
strainers. These strainers should be cleaned. Refer to 
Cleaning Steam Strainer.
All repairable traps should be opened at least once a 
year to visually check operating mechanisms.
Remove sediment and dirt from trap body. Mechanism 
may require cleaning by immersing in appropriate 
cleaning fluid.
NOTE: Check instructions provided with trap or 
with trap manufacturer for appropriate cleaning 
fluids.