beautypg.com

Power supply ­ mains control connections – OmniSistem PR Pilot 1200 Wash User Manual

Page 5

background image

Pilot 1200 wash

EN.doc

5/16

Connect the power cord as follows:

L (live) =brown
E (earth) =yellow/green
N (neutral) =blue

Use the plug provided to connect the mains power to the projector paying attention to the
voltage and frequency marked on the panel of the projector. It is recommended that each
projector be supplied separately so that they may be individually switched on or off.

IMPORTANT
It is essential that each projector is correctly earthed and the electrical installation
conforms to all relevant standards. Power consumption of the PILOT 1200 WASH is
1380W.

Connection between controller and projector and between one projector and another must
be made with 2 core­screened cable, with each core having at least a 0.5mm diameter.
Connection to and from the projector is via cannon 3 pin (which are included with the
projector) or 5 pin XLR plugs and sockets. The XLR's are connected as shown in the figure
above.
Note: care should be taken to ensure that none of the pins touch the metallic body of the
plug or each other. The body of the plug is not connected in any way. The PILOT 1200
WASH accepts digital control signals in protocol DMX512 (1990).
Connect the controller’s output to the first fixture’s input, and connect the first fixture’s
output to the second fixture’s input and connect the rest fixtures in the same way.
Eventually connect the last fixture’s output to a DMX terminator as shown in the figure
below.

DMX OUT

DMX IN

DMX OUT

DMX IN

TERMINATOR

DMX IN FROM CONTROLLER

DMX IN

DMX OUT

POWER SUPPLY ­ MAINS

CONTROL CONNECTIONS