beautypg.com

10 connecting the sensors to the canbus – NORAC UC5-BC-HG02 User Manual

Page 29

background image



26

10 Connecting the Sensors to the CANbus

1. Fasten the 8-way coupler to the boom with cable ties.

2. Connect the boom frame roll sensor (E04) to the 8-way coupler (E11) using cable C05 and

a 2-way coupler (E12).

3. Connect the main lift sensor to the 8-way coupler using cable C03 and a 2-way coupler

(E12). Cable C03 and item E12 may not be needed if the 8-way coupler is mounted close
enough to the main lift sensor.

4. Connect two cables (C06) to the 8-way coupler (E11) and route along the booms to the

wing sensors. Follow existing cables and hoses to be sure the cable will not be pinched or
stretched.

Figure 24: UC5 Module Locations and Cable Connections

5. At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.

The 2-way coupler with terminator is the white two way coupler. Plug the sensor and the
CANbus cable into the 2-way coupler.

Ensure that all unused connectors are plugged with the plugs provided.