beautypg.com

NORAC UC5-BC-HG02 User Manual

Page 19

background image



16

7.2 Roll Sensor Mounting Guidelines: Front Mounted Rigid Booms

1. When mounting the roll sensors, mount one to the boom and one to the chassis near the

sprayer cab.

Figure 13: Roll Sensor Mounting on a Front Mounted Rigid Boom

2. Ensure the roll sensors are relatively level when the sprayer boom and chassis are level.

3. Both roll sensor cables must be pointing towards the right hand wing of the sprayer when

looking from the rear of the sprayer.

4. Ensure both roll sensors are mounted adequately and that the cables provide enough slack

to allow sufficient boom roll.