8 hydraulic installation, 1 valve assembly – NORAC UC5-BC-HG01 User Manual
Page 21

 
 
 
18
8 Hydraulic Installation
Ensure all pressure has been bled from the system before disconnecting any lines 
or fittings. Hydraulic pressure will exist on the wing tilt circuits unless the wings 
are being supported by other means. The hydraulic installation may be performed 
with the wings in transport position, resting on the ground or with the tilt cylinders 
fully extended. 
Component failure due to oil contamination is not covered under the NORAC UC5 
system warranty. It is recommended that a qualified technician perform the 
hydraulic installation. 
8.1 Valve Assembly
1. On a clean surface remove the plastic plugs from the block.
2. Install the 6MB-6MJ (F05) fittings into the “P” and “T” ports. Tighten to 18 ft-lbs (24 Nm).
3. Insert two orifices (F08) into the B ports with the notch facing out.
4. Install the 6MB-6MJ (F05) fittings into the “B” ports. Tighten to 18 ft-lbs (24 Nm).
5. Insert two orifices (F08) into the “A” ports with the notch facing in.
6. Install the 6MB-6MJ (F05) fittings into the “A” ports. Tighten to 18 ft-lbs (24 Nm).
Figure 16: NORAC Valve Block Details