7.3 Boom-Frame Roll Sensor Mounting

1. Install the roll sensor with the lowest serial number onto the top part of the center boom

section on the left hand side of the boom. The roll sensor must be mounted with the

connector facing the right boom when viewed from the rear of the sprayer.

Figure 14: Hagie Boom Frame Roll Sensor Mounting

Ensure the boom frame roll sensor does not collide with any parts and the cable
has sufficient slack for the boom to travel though its entire range of motion.