8.3 Input Module
1. Install the input module (E03) on the boom near the sprayer valve block. Secure it to the
boom using cable ties or optional brackets.
2. Connect the free end of the CANbus cable (C02) from the valve module to the input
module.
3. Insert the 12-pin plug (P02) into the OEM 3 connector on the end of the input module.
4. Connect the 12-pin connector on the tilt interface cable (C20) to the Thru 2 connector on
the side of the input module.
5. Insert the 2-pin connector tees on C20 into the corresponding tilt connectors on the
sprayer valve block.
Figure 25: Input Module Connections
6. Connect the 12-pin connector on the main lift interface cable (C21) to the Thru 1
connector on the side of the input module.
7. Insert the 2-pin connector tees on C21 into the corresponding main lift connectors on the
sprayer valve block.
8. If the sprayer has a bypass valve, insert the 2-pin tee connector marked “Aux 1” into the
bypass valve connection. If the sprayer does not have a bypass valve, connect the male and
female “Aux 1” connectors together.
9. Connect the male and female “Aux 2” connectors together.