beautypg.com

6 main lift sensor installation – NORAC UC5-BC-TA01 User Manual

Page 19

background image



16

6.6 Main Lift Sensor Installation

Figure 13: Main Lift Bracket Assembly

1. There are a variety of ways to mount the main lift bracket on most sprayers. The bracket

should position the sensor approximately in the center of the sprayer, forward of the
boom. An example of this mounting is illustrated in Figure 14.

2. Mount the ultrasonic sensor to the main lift bracket. Run the sensor cable down the center

of the main lift bracket tube.

Figure 14: Example Mounting of the Main Lift Bracket

Avoid mounting the main lift sensor over or near a wheel-track. Measurements
from the wheel-track do not provide an accurate crop height and will cause
measurement and control error.

Ensure the bracket does not collide with any other part of the sprayer throughout
the full range of main lift motion.