9.2 Valve Assembly: Double Acting

1. On a clean surface remove the plastic plugs from the block.

2. Install 6MB 6MOR (F02) fittings into the “P” and “T” ports on the NORAC block. Tighten

to 18 ft-lbs (24 Nm).

3. Insert orifices (F01) into the “B” ports with the notch facing out.

4. Install 6MB 6MOR (F02) fittings into the “B” ports on the NORAC block. Tighten to 18 ft-

lbs (24 Nm).

5. Insert orifices (F01) into the “A” ports with the notch facing in.

6. Install 6MB 6MOR (F02) fittings into the “A” ports on the NORAC block. Tighten to 18 ft-

lbs (24 Nm).

Figure 26: NORAC Valve Block Details