beautypg.com

3 input module – NORAC UC5-BC-FT03 User Manual

Page 24

background image



21

8.3 Input Module

1. Install the input module (E03) on the boom near the Fast valve block. Secure it to the

boom using cable ties or optional brackets. Insert the 12 pin plug (P02) into the OEM 3

connector on the end of the input module.

2. Connect the free end of the CANbus cable (C02) from the valve module to the input

module. Connect cable C03 to the other CANbus connector.

3. Connect the 12 pin connector on the tilt interface cable (C20) to the Thru 2 connector on

the side of the input module.

4. On the interface cable (C20), connect “Left Up” to “Left” on the Fast valve block and “Right

Up” to “Right”.

5. Connect the unused male and female connectors on “Left Down” to each other and

connect the unused male and female connectors on “Right Down” to each other.

Figure 24: Input Module Connections

6. Connect the 12 pin connector on the main lift interface cable (C21) to the Thru 1

connector on the side of the input module.

7. Insert the “Aux 2” tee between the Fast directional cartridge and the existing cable.

8. Insert the “Main Up” tee between the Fast “Main” function cartridge and the existing cable.

9. Connect the unused male and female connectors on “Main Down” to each other

10. If the sprayer has a bypass valve, insert the 2-pin tee connector marked “AUX 1” into the

bypass valve connection. If the sprayer does not have a bypass valve, connect the plug and
receptacle “Aux 1” connectors together.