beautypg.com

3 hydraulic installation – NORAC UC4+SM3-4B User Manual

Page 8

background image

5

3

HYDRAULIC INSTALLATION

WARNING!

The hydraulic system creates very
high pressure. Before disconnecting
any hydraulic lines ensure all pressure
has been bled from the system.

IMPORTANT:

Component failure due to oil
contamination is not covered under
the UC4+ Spray Height Control
system warranty. It is recommended
that a qualified technician does the
hydraulic installation.

1. On a clean surface remove all plastic

plugs from the NORAC expansion valve
block (V01).

2. Install the 6MBP (F03) into the A port

of the expansion block (Figure 2).

3. Install the 6MB 6MJ fitting (F04) into

the B port of the expansion block
(Figure 2).

Figure 2: Third Station Expansion

Block Assembly

4. Coat the four o-rings in hydraulic oil

and install them into the expansion
block. Ensure the o-rings are seated
properly.

5. Attach the expansion block to the 2

station block using the included spring
washers and bolts.

6. Tighten the bolts to 31 ft-lbs.

Figure 3: Expansion Valve Final Assembly