11

4.3 R

OLL

S

ENSOR

I

NSTALLATION

To mount the roll sensors, the roll sensor
brackets will have to be bent. The brackets
are supplied with a 90° bend and must be
bent to a 45° bend to fit properly on the
frame members.

Mount the roll sensors to the included roll
sensor brackets using the machine screws

and nylon lock nuts, as illustrated in Figure
13
.

The roll sensors must be

mounted tightly to the brackets.

Figure 13: Mounting the Roll Sensor

to the Roll Sensor Mounting Bracket

When mounting the roll sensors use the
following guidelines and refer to Figure 14.

1. Ensure the roll sensors are sitting

relatively level when the sprayer chassis
and boom are level.

2. Both roll sensors must be mounted

with the circular AMP connector facing

towards the Right-Hand Wing (when
looking from the rear of the sprayer).