1. Assemble the main lift sensor bracket

(B11) as shown in Figure 10.

Figure 10 – Main Lift Sensor Bracket

2. The bracket should be mounted to the

lowest frame member on the center
section of the sprayer. The bracket
should be mounted so the sensor
mounting collar is approximately in the
center of the sprayer.

Make sure the sensor has

clearance when the main
section is raised and lowered.

3. Mount the sensor onto the sensor

mounting collar.

4. The final assembly is shown in Figure

11.

Figure 11 – Main Lift Sensor Bracket

Mounting Position

General mounting rules for
ultrasonic main lift sensor:

a) Mount the sensor at the midpoint of

the main lift section.

b) The sensor must have a 12-inch

diameter clear view of the ground
without any obstructions.

c) Ensure that there will be no contact

between the sensor and the booms
when folding and unfolding, or
raising and lowering.

d) The bottom of the sensor must be

at least 9 inches in front or behind
the spray nozzles.

e) The bottom of the sensor must be

at least 9 inches above the spray
nozzles.

Figure 12 – Example of Main Lift

Sensor Mounting on Front Mounted

Boom

Bracket Tube

Sensor

Mounting Tab

Sensor Mounting

Collar

Bracket Base