4 main lift sensor installation – NORAC UC4+BC+JD10 User Manual

Page 17

background image

14

4.4 M

AIN

L

IFT

S

ENSOR

I

NSTALLATION

1. Assemble the main lift sensor bracket (B11)

as shown in Figure 13.

Figure 13: Main Lift Sensor Bracket

2. The bracket can then be mounted to the

lowest frame member on the center section
of the sprayer. The bracket should be
mounted so the sensor mounting collar is in
approximately the center of the sprayer and
ahead of the boom (Figure 14 and Figure
15)
.

The sensor mounting collar must not

be behind the sprayer’s wheel.

Figure 14: Main Lift Sensor Bracket

Mounting Position

3.

Mount the sensor onto the sensor

mounting collar (Figure 14).

Figure 15: Main Lift Sensor Mounted in

the Correct Location

General Mounting Rules for UC4+
Ultrasonic Sensors:

a) In its lowest position, the sensor mouth

must be 9 inches or more from the ground.

b) The bottom of the sensor must be at least 9

inches in front of the spray nozzles.

c) The bottom of the sensor must be at least 9

inches above the spray nozzles.

d) Ensure that there are no obstructions within

a 12-inch diameter circle projected directly
below the center of the sensor.

e) The sensor should be approximately vertical

at normal operating heights.

Bracket Tube

Sensor

Mounting Tab

Sensor Mounting

Collar

Bracket Base