beautypg.com

2 valve mounting – NORAC UC4+BC+CS1 User Manual

Page 21

background image

18

4.6.2 Valve Mounting
1. Mount the NORAC valve (V01) on the

sprayer using the valve mounting
bracket (B10).

2. As shown in Figure 22, screw short

side of the threaded rods into the
bottom of the valve block at least 3/8".
The valve mounting holes are drilled and

tapped 3/8 NC-1" deep.

3. Tighten the Hex nuts to hold the rods.

4. Put the mounting bracket on the other

side of the tube and tighten with the
spring washers and the Hex nuts.

5. Cut excess off of the studs, if necessary.

If using bolts, the bolts should

thread into the valve block at
least 3/8". The valve mounting
holes are drilled and tapped 3/8

NC-1" deep. The rule of thumb
for bolt length is 1-1/2" longer
than the tube size.

The recommended location for

the valve is on top of the hose
mounting frame located almost
to the top of the boom. The
frame is made from smaller
tubing and projects rearward
from the main boom section.

You must ensure no hydraulic

components will interfere with
any sprayer parts or be pulled
tight at any time.

You must also ensure there are

no other orifices present in the
circuit between the NORAC
valve block and the boom
cylinders.

Figure 22: Valve Mounting Location

Figure 23: Valve Mounting Example

Cylinder “A”

Line

H04

F07

H04