3 wing sensor installation – NORAC UC4+BC+CS1 User Manual
Page 12
9
4.3 W
ING
S
ENSOR
I
NSTALLATION
1. Mount the Low Profile Sensor Mounting
Brackets (B20) onto the boom as show
in Figure 4 and Figure 5 with the
mounting base in front of the tube.
Figure 4: Low Profile Bracket
Mounting
Figure 5: Low Profile Bracket
Mounted on Boom
If possible, mount the sensor
brackets while the booms are in
their folded position to ensure
that they will not interfere with
anything when the boom is folded
for transport.
Mounting the sensor bracket to
the break-away section of the
boom may cause the boom to
drop suddenly as a break-away
occurs. This will occur on break-
away sections which lift as they
break away.
For optimal boom tip protection,
it is recommended that the
sensor be mounted within
approximately two feet (60cm) of
the boom tip.
Please refer to the UC4+ system
warranty at the end of the UC4+
Sprayer Boom Control Operator’s
Manual (M01) for implications.
2. Mount the NORAC UC4+ ultrasonic
sensors (E02) into the sensor brackets.
The sensors should be oriented forward
(ahead) of the boom.
When installing the UC4+
sensors (E02), start with the
smallest serial number on the left
hand side proceeding to the
largest serial number on the right
hand side (Figure 11).
3. Sensor cables should run either through
hole in the back or through the side
cut-out and behind the bracket. Ensure
the cable is clear of moving parts and
will not be damaged during folding.
Cable-tie the connector in place. The
cable must not hang below the boom.
Front