beautypg.com

6 hydraulic installation, 1 valve assembly – NORAC UC4+BC+AP3 User Manual

Page 21

background image

18

4.6 H

YDRAULIC

I

NSTALLATION

WARNING!

The hydraulic system creates very
high pressure. Before disconnecting
any hydraulic lines ensure all pressure
has been bled from the system.

When changing the boom hydraulic
hoses leave the booms in
TRANSPORT POSITION.

IMPORTANT:

Component failure due to oil
contamination is not covered under
the UC4+ Spray Height Control
system warranty. It is recommended
that a qualified technician does the
hydraulic installation.

4.6.1 Valve Assembly
1. On a clean surface remove all plastic

plugs from the NORAC hydraulic Valve
(V01) (Figure 22).

Figure 22: NORAC Valve Block

2. Install the orifices (F08) into the "B"

ports with the notch facing outward
as shown in Figure 23.

3. Install the 6MB-6MJ fittings (F05) into

the “B” ports and tighten to 18 ft-lbs.

4.

Install the 6MBP plugs (F09) into the
“A” ports and tighten to 18 ft-lbs.

Figure 23: Valve Block Assembly