6.2 Roll Sensor Mounting Guidelines: Front Mounted Rigid Booms

1. When mounting the roll sensors, mount the roll sensor with the temperature probe on the

boom and the roll sensor without the temperature probe on the chassis near the sprayer

cab.

Figure 12: Roll Sensor Mounting on a Trapeze Suspended Boom

2. Ensure the roll sensors are relatively level when the sprayer boom and chassis are level.

3. Both roll sensor cables should be pointing towards the right hand wing of the sprayer.

4. Ensure both roll sensors are mounted adequately and that the cables provide enough slack

to allow sufficient boom roll.

6.3 Temperature Probe

Once the block is mounted, fasten the temperature probe from E03 to the NORAC valve

block using the included 3/8x1/2” bolt as illustrated in Figure 13.

Figure 13: NORAC Valve Block with Temperature Probe Installed