beautypg.com

4 wing sensor installation – NORAC UC4.5-BC-JD11 User Manual

Page 14

background image



12

5.4 Wing Sensor Installation

1. The sensor bracket should be oriented forward (ahead of the boom).

2. Typically the best mounting location for the wing sensor brackets will be near the end of

the boom tips, approximately two feet (60cm) from the end.

3. Depending on the boom design, some breakaway sections will lift upwards as they break

back. If the sensor is mounted to this portion of the boom, the system will force the boom
downwards towards the ground as the boom folds backwards.

4. Mount the NORAC ultrasonic sensor into the sensor bracket and run the sensor cable

either through hole in the back or through the side cut-out and behind the bracket. Ensure
the cable is clear of moving parts and will not be damaged during folding.

Figure 8: Bracket Mounting Example

Front