NORAC UC4.5-BC-AP3 User Manual
Page 18
15
6.2
Roll Sensor Mounting Guidelines: Trapeze-Suspended Booms
1. When mounting the roll sensors, mount a roll sensor without the temperature probe
(E04) with the lowest serial number on the trapeze link (boom frame), a roll sensor
without the temperature probe (E04) with the highest serial number on the chassis
(reference frame), and the roll sensor with the temperature probe (E03) on the boom
carrier frame (intermediate frame). For optimal performance, minimize the distance from
the boom frame roll sensor to the pivot point (A) and minimize the vertical distance
between the chassis roll sensor and the pivot point (B).
Figure 16: Roll Sensor Mounting on a Trapeze Suspended Boom
2. The reference frame (chassis) roll sensor has the highest serial number (E04) and mounts as
shown in Figure 17.
Figure 17: Reference Frame Roll Sensor Mounting Location
3. Ensure the roll sensors are relatively level when the sprayer boom and chassis are level.
4. Both roll sensor cables should be pointing towards the right hand wing of the sprayer.
5. Ensure both roll sensors are mounted adequately and that the cables provide enough slack
to allow sufficient boom roll.