If you are using an extension cord

6.

outdoors, make sure it is marked with

the suffix “W-A” (“W” in Canada) to

indicate it is acceptable for outdoor

use.
Make sure the extension cord is prop-

7.

erly wired and in good electrical con-

dition. Always replace a damaged

extension cord or have it repaired by

a qualified electrician before using it.
Protect the extension cords from

8.

sharp objects, excessive heat, and

damp or wet areas.

rEcOmmENdEd miNimum WirE

gaugE FOr EXtENSiON cOrdS*

(120/240 VOlt)

NamEplatE

ampErES

(at full load)

EXtENSiON cOrd

lENgtH

25’

50’

75’

100’

150’

0 – 2.0

18

18

18

18

16

2.1 – 3.4

18

18

18

16

14

3.5 – 5.0

18

18

16

14

12

5.1 – 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1 – 16.0

14

12

10

-

-

16.1 – 20.0

12

10

-

-

-

taBlE a

* Based on limiting the line

voltage drop to five volts at

150% of the rated amperes.