APPLICATION INFORMATION

This hoist is intended for general industrial use for lifting and

transporting freely suspended material loads within its rated

capacity. MILWAUKEE cannot be responsible for applications

other than those for which MILWAUKEE equipment is

recommended. Prior to installation and operation, we caution

the user to review his application for abnormal environmental

or handling conditions and to observe the applicable

recommendations as follows:

ADVERSE ENVIRONMENTAL CONDITIONS

Do not use the hoist in areas containing flammable vapors,

liquids, gases or any combustible dusts or fibers. Refer to

Article 500 of the National Electrical Code. Do not use this

hoist in highly corrosive, abrasive or wet environments. Do not

use this hoist in applications involving extended exposure to

ambient temperatures below -10°F or above 130°F.

LIFTING OF HAZARDOUS LOADS

This hoist is not recommended for use in lifting or transporting

hazardous loads or materials which could cause widespread

damage if dropped. The lifting of loads which could explode or

create chemical or radioactive contamination if dropped

requires fail-safe redundant supporting devices which are not

incorporated into this hoist.

LIFTING OF GUIDED LOADS

This hoist is not recommended for use in the lifting of guided

loads, including dumbwaiters and elevators. Such applications

require additional protective devices which are not

incorporated into this hoist. For such applications, refer to the

requirements of applicable state and local codes, and the

American National Safety Code for elevators, dumbwaiters,

escalators and moving walks (ASME A17.1).

SAFETY INFORMATION

1. Follow all local electrical and safety codes, as well as the

National Electrical Code (NEC) and the Occupational

Safety and Health Act (OSHA) in the United States.

2. Hoist must be securely and adequately grounded. The hoist

power cable is provided with an additional lead (green) for

grounding purposes.

3. Be careful when touching the exterior of an operating

motor; it may be hot enough to be painful or cause injury.

With modern motors this condition is normal if operated at

rated load and voltage (modern motors are built to operate

at higher temperatures).

4. Protect the power cable and control cable from coming in

contact with sharp objects.

5. Do not kink power cable and control cable and never allow

the cable to come in contact with oil, grease, hot surfaces,

or chemicals.

6. Make certain that the power source conforms to the

requirements of your equipment.

7. Inspect the unit daily before operating hoist.
8. Cluttered areas and benches invite accidents.
9. The operator should not engage in any practice which will

divert his attention while operating the hoist.

10. Before using the hoist, the operator should be certain that

all personnel are clear.

11. Do not operate hoist with loads exceeding its rated capacity.
12. Supporting frames or beams used as a hoist hanger must

have a greater load capacity than the hoist.

13. Do not attempt to operate hoist beyond normal maximum

lift range.

14. Align hoist for a straight line pull. Avoid side pull or end pull.
15. Do not operate hoist with twisted or damaged chain.
16. Do not operate a damaged or malfunctioning hoist until

necessary adjustments or repairs have been made.

17. Do not use hoist to lift people or to carry loads over people.
18. Do not leave a load suspended in the air unattended.
19. Always remove load before making repairs.
20. Do not remove or obscure capacity or warning decals.

INSTALLATION

1. Before installing the hoist, check the following:

a. Make sure all supporting structures and attaching devices

are strong enough to hold your intended loads. If in doubt,

consult a qualified structural engineer.

b. Provide proper branch circuit protection for the hoist as

recommended in the National Electrical Code.

c. The power supply should be within plus or minus 10% of

the voltage specified on the motor nameplate. It is critical

to use adequate sized power cables, especially with

1-phase hoists (See Table 3). Be sure dual voltage hoists

are connected or wired to correspond with your power

supply (See WIRING, page 9).

d. Installation area must provide operating conditions for the

operator including sufficient room for the operator and

other personnel to stand clear of the load at all times.

e. For installations where the slack chain hanging from the

unit may be objectionable or hazardous, the use of a

chain container is recommended. See INSTALLATION OF

CHAIN CONTAINER ASSEMBLY.

4

Milwaukee Electric Tool Corporation

13135 West Lisbon Road

Brookfield, Wisconsin 53005

TEL: (800) 729-3878

Always disconnect the power source before working

on or near a hoist or its connected load. If the power

disconnect point is out of sight, lock it in the open

position and tag to prevent unexpected application

of power.

Failure to comply with Safety Precautions outlined

throughout this manual can result in serious injuries

or death. Before using this hoist, each operator

should become thoroughly familiar with all warnings,

instructions and recommendations in this manual.

This manual is related to the following products: