beautypg.com

Milwaukee Tool 9566 V.2 User Manual

Page 3

background image

3

MILWAUKEE Electric Chain Hoists are rugged, portable hoists

that provide quick, precise lifting. The hoists are constructed of

tough, but lightweight, die cast aluminum alloy housings. An oil

bath transmission, equipped with heat-treated, alloy steel

gears and an overload limiting clutch, provides smooth and

reliable operation.

With a pushbutton station that fits comfortably in one hand, the

operator can safely control the hoist while the other hand is

free to guide the load. The electrical controls, which are readily

accessed under the electrical cover, utilize quick connections

for easy voltage conversions and a 24V control circuit for

added safety.

Other features that ensure the safe operation of MILWAUKEE

Electric Chain Hoists include a magnetic disc brake that

delivers sure stopping and secure holding of the load.

Adjustable upper and lower limit switches regulate the load

travel. As a standard, hooks are supplied with safety latches.

For additional safety, a chain stop is attached to the slack end

of the load chain.

MILWAUKEE Electric Chain Hoists are designed and tested in

accordance with the American Society of Mechanical

Engineers Code B30.16, “Safety Standard for Overhead

Hoists.” Hoists are built in compliance with CSA, file number

LR 44484. Made in U.S.A.

Milwaukee Electric Tool Corporation

13135 West Lisbon Road

Brookfield, Wisconsin 53005

TEL: (800) 729-3878

TABLE OF CONTENTS

Safety Precautions......................................................................................................................................................................2

Hoist Specifications.....................................................................................................................................................................3

Application Information ...............................................................................................................................................................4

Safety Information .......................................................................................................................................................................4

Installation ...................................................................................................................................................................................4

Operation ....................................................................................................................................................................................5

Maintenance ...............................................................................................................................................................................6

Wiring Diagrams .......................................................................................................................................................................12

Trouble Shooting .......................................................................................................................................................................13

Inspection and Maintenance Check List ...................................................................................................................................14

Recommended Lubrication Schedule.......................................................................................................................................15

Replacement Parts List.............................................................................................................................................................16

Parts Depot & Warranty Repair Centers...................................................................................................................................28

Warranty .....................................................................................................................................................................Back Cover

Lifting

Control Cord

Full Load

Model

Capacity

Speed

Lift

Length

Reeving

HP

Voltage

Motor Amps

*

Phase

(tons)

(fpm)

(ft)

(ft)

(AC)

Table 1 - Hoist Specifications

9560

1/2

16

10

6

Single-chained

1/2

115/230V

7.6/3.8

Single

9573

2

8

20

16

Double-chained

1

115/230V

14/7**

Single

9570

2

8

10

6

Double-chained

1

115/230V

14/7**

Single

9567

1

16

15

11

Single-chained

1

115/230V

14/7**

Single

9568

1

16

20

16

Single-chained

1

115/230V

14/7**

Single

9566

1

16

10

6

Single-chained

1

230/460V

3.2/1.6

Three

9565

1

16

10

6

Single-chained

1

115/230V

14/7**

Single

9562

1/2

16

20

16

Single-chained

1/2

115/230V

7.6/3.8

Single

9561

1/2

16

15

11

Single-chained

1/2

115/230V

7.6/3.8

Single

9572

2

8

15

11

Double-chained

1

115/230V

14/7**

Single

9571

2

8

10

6

Double-chained

1

230/460V

3.2/1.6

Three

*

At full load, it is not unusual for the hoist to draw in excess of

the values listed when lifting. It is critical to ensure that the

voltage at the hoist contactor does not drop below 10% of

the nominal voltage of the hoist while it is lifting a load. Low

voltage will result in higher amp draw, damage to the hoist,

and potential fire hazards. MILWAUKEE is not responsible

for any damages caused by an inadequate power source.

**

The 1HP, 115/230V models must have a dedicated power

circuit rated for at least 20A, 125V when they are wired for

115V. It is not unusual for these models to draw up to 20

amps at 115V when lifting at rated capacity. Refer to

Table 3 before installation.

HOIST SPECIFICATIONS

This manual is related to the following products: