MIDI Solutions F8 8-input MIDI Footswitch Controller User Manual
Page 5

F0 00 00 50 24 00 02 ii bb cc dd (ee) F7
ee
ii
bb
bb
cc
cc
dd
dd
dd
cc
ee
ee
F0 00 00 50 24 00 03 (00) tt F7
00
tt
00
tt
64
(
is optional)
= Footswitch Input (00 for Fsw1 ... 07 for Fsw8)
= 00: Toggle OFF
= 01: Toggle ON
= 00: Auto Polarity OFF
= 01: Auto Polarity ON
= 00: Normally OPEN polarity
= 01: Normally CLOSED polarity
(
is ignored if
= 01)
is optional. If
= 7F, the F8 waits for the beginning of the next bar to perform the footswitch action
(
is optional)
All bytes must be in Hexadecimal format (see hexadecimal conversion table at end)
= Debounce time in ms
is optional, if included the above debounce time
is doubled
The clear settings command resets the debounce time to 50 ms
System Exclusive
following System Exclusive programming
command:
F0 00 00 50 24 00 03
F7
To program the F8 to echo incoming MIDI messages to the MIDI output and send nothing on power-up, send it the
following System Exclusive programming command:
F0 00 00 50 24 00 01
F7
To program the toggle parameter of Fsw8 to ON and force the polarity to NORMALLY OPEN, send the F8 the
following
programming command:
F0 00 00 50 24 00 02
F7
To program the footswitch debounce time to 100 ms send the F8 the
Examples
01
07 01 00 00
5