Configuration
The configuration commands described in this section modify basic dialer operation and
store information about the dialer’s operational behavior in nonvolatile memory. You
should only have to configure your dialer once -- all changes are saved permanently,
even if AC and battery power are removed from your dialer. This section consists of the
following subsections:
z Basic System Information - Set/Query various system values.
z Telephone Numbers - Set/Query each of the outgoing phone numbers.
z Fault Inputs - Set/Query each fault input channel configuration.
z Email address – Set/Query an email address to receive wireless email alerts.
The following abbreviations are used in the manual to represent user-selected inputs in
the Dialer configuration commands:
Abbreviation Meaning
c
Fault Input Channel Number, 1-5 (5 = power-fail)
~ Recorded
speech
n
1 digit numeric data
nn
2 digit numeric data
p
Variable length Telephone number (up to 30 digits) with escape
codes
“”
Text between “” marks represents SMS text messages.
Basic System Information
The following commands configure and report the current values for the system level
information of the CellStat
TM
. A Glossary of Dialer Terminology that defines these
parameters with respect to CellStat
TM
operation is provided in the Appendix B.
z Voice System Name The message the dialer will speak before making any report.
*01
Play system name
**01~
Record system name
Once the command to Record the system name has been typed in, the dialer will
speak “Ready” as a prompt for you to begin speaking. Speak the message up to 10
seconds in length. When finished the dialer will play back for your review.
Example voice response-
Jonesburg remote site number 6 (recorded)