2.24 M1X22_StartMeasureVoltage
Description
Start the line voltage measurement process.
Prototype
int M1X22_StartMeasureVoltage (
M1X22_HANDLE channel,
unsigned int sampleTime,
unsigned int averageSampleCount );
Parameters
Data Type
Name
Description
channel
Channel handle obtained from open channel.
unsigned int
sampleTime
Time interval between two consecutive samples.
unsigned int
averageSampleCount Sample count for average calculation.
Return Values
Data Type
Description
M1X22_RET
M1X22_SUCCESS – Successfully started.
M1X22_FAILED –Failure.
2.25 M1X22_StopMeasureCurrent
Description
Stop the line current measurement.
Prototype
int M1X22_StopMeasureCurrent (
M1X22_HANDLE channel,
unsigned int sampleTime,
unsigned int averageSampleCount );
Parameters
Data Type
Name
Description
channel
Channel handle obtained from open channel.
unsigned int
sampleTime
Time interval between two consecutive samples.
unsigned int
averageSampleCount Sample count for average calculation.
Return Values
Data Type
Description
M1X22_RET
M1X22_SUCCESS – Successfully stopped.
M1X22_FAILED – Failure.