Panel controls 2 – Make Noise René User Manual
Page 6
![background image](/manuals/698370/6/background.png)
Inputs (Continued)
7. Y- CV Input: control signal at this input generate a number that is added to the
number generated by the Y- Axis Counter, to create the Y coordinate. When René counts
Snake Style, Y- CV selects stored set of coordinates.. Y- CV is normalled to +5V so that with
nothing patched the attenuator acts as an offset generator.
8. Y-CV Input CV Attenuator
Outputs:
10. QCV: The Quantized Control Voltage for the currently active location will appear at this output. QCV
may also yield a Stored Quantized Voltage (if selected on Q Page), in which case the
corresponding location potentiometer is no longer “live.” Value, 4 octaves.
12. Gate X: this output reflects the ProGraMming on the X-Gate Page. When René arrives at a location,
and the location is set to ON (lighted) at the X-Gate PGM Page, this output goes HI for
duration determined by the XCLK width and any ProGraMmed Logic Operations that Axis Clock
or Gate.
When counting SNAKE style, the Gate output is always a skinny pulse (2ms) perfect for
ringing LoPass Gates. Value, 0V or +8V. Gate Y: this output reflects the ProGraMming on the
Y- Gate Page. When René arrives at a location, and the location is set to ON (lighted) at the
Y- Gate PGM Page, this output goes HI for duration determined by the YCLK width and any
ProGraMmed Logic Operations affecting the Axis Clock or Gate. When counting SNAKE
style, the Gate output is always a skinny pulse (2ms) perfect for ringing LoPass Gates. Value,
0V or +8V.
13. Gate Y: this output reflects the ProGraMming on the Y‐Gate Page. When René arrives at a location,
and the location is set to ON (lighted) at the Y‐Gate PGM Page, this output goes HI for duration
determined by the YCLK width and any ProGraMmed Logic Operations affecting the Axis Clock
or Gate. When counting SNAKE style, the Gate output is always a skinny pulse (2ms) perfect
for ringing LoPass Gates. Value, 0V or +8V.
Interface:
14. CV ProGraMming Grid
15. Gate Y Activity Indicator LED
16. Gate X Activity Indicator LED
17. ProGraM Page Select; PGM 1
18. Return to Play, PGM 2: Hold to store settings.
19. Indicate Latch (Hold) or Indicate Active Program Page
20. Touch Grid: Flashes to indicate storage taking place.
9. Touch Grid sensitivity control.
To increase sensitivity, set the position 100% clockwise.
Sensitivity:
11. CV: An unquantized Control Voltage of the currently selected location will appear at this output. At
the CV OUT, the location potentiometers are always “live.” Value 0 to 4.5V