Chapter 9 Specifications

− 56 −

9.2 Interfaces

1 Serial interface

Specifications

Transfer method:

Start stop synchronous dual communication system

Signal level:

RS-232C

Baud rate:

2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200 bps

Data bits:

7 or 8

Start bits:

1

Stop bits:

1 or 2

Parity:

Even, odd, or none

Connector:

D-SUB 25PIN 17LE-13250-27(D41)(DDK) or its equivalent

XON/XOFF protocol

XON code output requirements:

• Communication is enabled after power is turned ON.
• Residual capacity of the buffer is 1K bytes or more after sending XOFF code.
• XOFF code is output due to error and printer returns to normal conditions.

XOFF code output requirements:

• Printer is in error.
• Printer is in paused state.
• Receive buffer has less than 128 bytes available.