TROUBLESHOOTING CHART
SYSTEM WILL NOT TURN ON AND ON/OFF INDICATOR LIGHT DOES NOT ILLUMINATE
PROBABLE CAUSE
CORRECTIVE ACTION
Coach Ignition not in RUN position
Turn ignition to RUN position
Parking brake not set
Set parking brake
Controls have been on for more than four
Turn ignition OFF and then back ON
minutes and have timed out.
CONTROL PAD TURNS ON BUT TURNS OFF WHEN LEG BUTTON IS PUSHED
PROBABLE CAUSE
CORRECTIVE ACTION
Low voltage on battery
Start coach to charge battery
CONTROL PAD TURNS ON, COACH WILL NOT AUTO-LEVEL, JACKS DOWN LIGHT IS ON, JACKS ARE
RETRACTED
PROBABLE CAUSE
CORRECTIVE ACTION
Low fluid level
Check fluid level in reservoir, if fluid is low
add fluid to FILL TO HERE line on reservoir
If JACKS DOWN light remains on call Lippert
Service.
JACKS WILL NOT EXTEND TO GROUND, PUMP IS RUNNING
PROBABLE CAUSE
CORRECTIVE ACTION
Little or no fluid in reservoir
Fill reservoir with DEXRON III ATF, See pg. 1
Leg valve is inoperative
Clean, repair or replace
Electronic signal is lost between control
Trace wires for voltage drop or loss of signal
and leg valves
Repair or replace necessary wires or replace
control pad
ANY ONE OR TWO JACKS WILL NOT RETRACT
PROBABLE CAUSE
CORRECTIVE ACTION
Hose damaged or unconnected
Replace with new hose or reconnect hose
Return valve inoperative
Replace inoperative return valve
Electronic signal is lost between control
Attempt to retract jacks in MANUAL mode.
and solenoid
If successful, replace control pad; if not, test
for voltage drop between control pad and leg
valve repair bad wiring or replace defective
board or valve.
“JACKS DOWN” LIGHT DOES NOT GO OUT WHEN ALL JACKS ARE RETRACTED
PROBABLE CAUSE
CORRECTIVE ACTION
Low fluid level
Fill reservoir to proper level with ATF, See pg. 1
Retract pressure switch inoperable
Check connection or replace
ALARM SOUNDS AND “JACKS DOWN” LIGHT STARTS FLASHING WHILE TRAVELING ACKS ARE FULLY RETRACTED
PROBABLE CAUSE
CORRECTIVE ACTION
Low fluid level
Fill reservoir to proper level with ATF, See pg. 1
Retract pressure switch inoperable
Check connection or replace
JACK BLEEDS DOWN AFTER BEING EXTENDED
PROBABLE CAUSE
CORRECTIVE ACTION
Valve Manual Override open
Close override, See pg. 7
CONTROL PAD POWERS UP; “LOW VOLTAGE” LIGHT FLASHES
PROBABLE CAUSE
CORRECTIVE ACTION
Engine not running
Start coach engine
“LOW VOLTAGE” LIGHT ON SOLID
PROBABLE CAUSE
CORRECTIVE ACTION
Charging system faulty
Turn key OFF; then, back ON again to reset
Check power and ground connections on
battery, alternator and chassis
NO POWER TO CONTROL PAD
PROBABLE CAUSE
CORRECTIVE ACTION
Tripped circuit breaker
Reset
Ignition not ON
Turn ON
www.lci1.com Toll free - (866) 524-7821