LAARS Mini-Therm JVi - Install and Operating Manual User Manual
Addendum to mini-therm jvi manual
Mini-Therm JVi Venting Material
10-27 December 14, 2010
To:
Manufacturer’s Representatives, Distributors, Contract Service Centers, Regional Sales Managers
and Internal Departments
From: Tom Gervais, International Sales Director
There has been an instance of confusion regarding suitable venting material for use on the Mini-Therm JVi
product within Canada. Therefore, the table used in section “1H-2: Horizontal Venting – Category III” of the
Mini-Them manual has been updated to more clearly indicate what is an allowable vent material.
In Canada: Use "BH-Type" vent materials certified to ULC-S636 Class I (more than 135°C, but not more
than 245°C flue gas temperature), made of AL29-4C stainless steel or equal.
'RQRWXVHSODVWLFYHQWLQJRIDQ\NLQG
800.900.9276 • Fax 800.559.1583 (Customer Service, Service Advisors)
20 INDUSTRIAL WAY, ROCHESTER, NH 03867 • 603.335.6300 • Fax 603.335.3355 (Technical Support)
1869 SISMET ROAD, MISSISSAUGA, ONTARIO, CANADA L4W 1W8 • 905.238.0100 • Fax 905.366.0130
Addendum to Mini-Therm JVi Manual
This Addendum applies to the following Documents:
Models Affected
Sizes
Part No.
Doc. No.
Mini-Therm JVi, JVH
50-225
H2020900D
Doc. 1080D
Page 8
Change to Column 2 Table:
1H-2. Horizontal Venting - Category III
(a) Vent Connections
Materials
Vent Length
In U.S.A.: UL type 304, 316 or 294-C
Up to a maximum
stainless steel, 26 gauge minimum.
of 55' (17m) of
In Canada: Use "BH-Type" vent
equivalent pipe
materials certified to ULC-S636
run (including
Class I (more than 135°C, but not
required elbows).
more than 245°C flue gas
temperature), made of AL29-4C
stainless steel or equal.