Ii - specifications – LAARS IGE-199C-5(N,X) - Service Manual User Manual
Page 9
II - SPECIFICATIONS
– GENERAL
Type of appliance
Temperature controlled continuous flow gas hot water system
Operation
With/without remote controls
Exhaust system
Direct Vent - Forced combustion
Model Type
Residential
Commercial
Maximum/Minimum
gas rate (Input Btu's)
199,000 Btu's – 15,000 Btu's Natural gas
199,000 Btu's – 15,000 Btu's Propane Gas
Thermal Efficiency
Natural Gas 84% Propane Gas 85%
Energy Factor (EF)
Natural Gas 0.82 Propane Gas 0.84
Capacity (Gallons 1st
Natural Gas 218 Propane Gas 227
Hour @ 90°F rise)
NO
x
Emissions (at 3% 02)
Less than 40 ppm
Hot water capacity (50°F rise)
0.5 to 6.5 GPM's
Setpoint Temperature
Factory setting - 120°F
(without remote)
Temperature range
BC-45-4US 96 - 120°F
MCC-45-4US 96 - 160°F
with remote keypads connected
BSC-45-4US 96 - 120°F
MC-45-4US 96 - 180°F
Approved gas type
Natural or Propane – Ensure unit matches gas supply type.
Installation
Outdoor installation ONLY
Dimensions
Height 23
5
⁄
8
"
Width 13
3
⁄
4
"
Depth 8
7
⁄
8
"
Weight
46 Lbs.
Noise levels
49 dB's
Connections
Gas supply
3
⁄
4
" MNPT
Cold water inlet
3
⁄
4
" MNPT
Hot water outlet
3
⁄
4
" MNPT
Ignition system
Direct electronic ignition
Electrical consumption
Operating
63 watts
Standby
5.5 watts
Anti-frost protection 84 watts
Water temperature control
Simulation feedforward and feedback
Water flow control
Water flow sensor and automatic electro-mechanical water
control device
Recommended Minimum water
supply pressure
20 PSI (recommend 50-80 PSI for maximum performance)
Maximum water supply pressure
150 PSI
9