Unable to adjust hot water temperature
1) Is the water temperature thermistor operating normally?
2) Is the change over solenoid (SV1) normal?
a.
# Disconnect the connector B5, and measure the
resistance between the white wires, see below
for resistance readings.
Thermistor resistance valves:
59 ºF
= 11.4 ~ 14 K Ω
86 ºF
=
6.4 ~ 7.8 K Ω
113 ºF
=
3.6 ~ 4.5 K Ω
140 ºF
=
2.2 ~ 2.7 K Ω
221 ºF
=
0.6 ~ 0.8 K Ω
Normal: Proceed to check item 2 below.
Faulty: Replace the water temperature
thermistor.
(Service Procedure IGE-6, page 48)
a.
# Disconnect the changeover solenoid (SV1)
connector, and measure resistance at the
solenoid terminals.
Normal: 1.7 ~ 2.1 K Ω
If normal, proceed to b.
Faulty: Replace the gas valve.
(Service Procedure IGE-9, page 50)
b.
Measure the voltage at the changeover solenoid
(SV1) yellow ~ black wires.
Normal: 80 ~ 100 VDC
If normal, proceed to check item 3, on next
page.
Faulty: Replace the PCB unit.
(Service Procedure IGE-2, page 47)
VI - TROUBLESHOOTING
(cont.)
BEFORE CARRYING OUT CHECKS MARKED WITH A # SIGN, DISCONNECT THE POWER SUPPLY.