Kuzma AIR LINE 2007-6 User Manual
Page 7
7
filters. On one end of this longer part is a valve. This end should be connected to the
red filters. The valve lever should be in »close position« ( i.e. with lever at 90 degrees
to the tube). When full air pressure is reached in the compressor ( and compressor
stops) open this valve and the air flowing into the red filters will automatically seal the
drain systems in these filters. There is, therefore, no need to do this manually as
before.
Compressor - rear view - air intake filter
Locate PVC bottle which has three black 'quick fit' fittings at the top end of bottle.
There are three black tubes (6mm in diameter), which drain moisture from various
parts of the compressor (reservoir, filter, cylinder). Push them into the top of the
fitting on the bottle.
Compressor - oil level
Plug the compressor into the mains. The switch is under the cover on the top. It has
two positions. Be careful inside not to hurt your fingers, although there is no danger
of electrical shock. Switch on the compressor and you will see the pressure building
up on the pressure gauge on the left side of the compressor. This shows the air
pressure in the reservoir. The right hand pressure gauge shows working pressure. It
should reach 4.5 bars (65 psi). The knob on top of the filter is for readjusting the
working pressure. To operate, it must first be pulled up.
Note: red filter ( dryers ):
Sealing red filters (dryers): When switching on compressor, air pressure must build up
in red filters. See section Dryer on the next page. See arrow for airflow!
Air intake filter