Problems

Cartridge skips the groove:
Tonearm is not horizontal: check horizontality
Excessive dirt on record: check and clean for small particles stuck in the groove
Inaccurate geometry: check that the cartridge tip follows line
Low tracking force
Moisture or dirt in the bearing: clean and check PVC bottle and Red filters stands
clean shaft and bearing with alcohol- see # 11

Cartridge does not cue first groove but runs in:
Tonearm is tilted down toward the centre of the record : adjust horizontal level down.
See above

Cartridge runs from record outwards:
Tonearm is tilted up towards the edge of the record: adjust horizontal level upwards.

Compressor can not generate enough pressure or runs longer than normal:
Check that the red filters drainage system is sealed
Leaking in the system: check tubes, filters, drain bottle at the compressor.

Compressor does not start:
Caused by overheating from being in closed space. Switch off and wait to cool down
for 1-2 hours
Check the mains electricity.

Compressor switching noise through the speakers:
The compressor has the same effect as household refrigerators which generate noise
wehen switching on or off. Some systems are more sensitive than others. If possible
the compressor should be connected to a secondary electrical circuit then the audio
system. If this is not possible then the compressor should be as far away as possible
from the audio system connected to the mains. A noise filter on the compressor
together with a long mains cable might help. See also Zero Switching kit.