Menu setting table (2/2), 37 printer operation, Mode settings – Citizen Systems Citizen CLP 621 CLP-621 User Manual
Page 37
37
Printer Operation
Top Menu
Sub Menu
Default
Menu
Remarks
Off ... Auto configure ineffective.
When a peeler unit or auto-cutter is
installed but has not been started, it is
off and the operation is selected by
“Function select”.
Function Select
Tear
Off
Selects the type of options installed and
Tear
adjusts the "paper stop" position accordingly.
Peel On*
For example, the position where the label
Cut On*
stops in "Tear" mode is different to that in
"Peel On" mode.
Cutter Action*
Backfeed
Backfeed
Cutter operating method setting
Through
Backfeed: it feeds back after each cutting
operation.
Through: when the number copied = n, the
back end of sheet 1 to n-1 passes through,
and the back end of the final page that is a
single sheet is copied and fed back.
Paper Position
0.00IN
Peel/Cut/Tear Off
T he stop position can be fine tuned using
0.00mm
0.00 to 2.00 IN
this menu setting. The general stop position
0.0 to 50.8mm
is selected depending on the "Function"
Peel/Cut/Tear On
selected above.
-1.00 to 1.00 IN
-25.4 to 25.4mm
Mode/Repeat Key
Disabled
LabelSet
Repeat method selection
LastOne
LabelSet:
Disabled
Reissues multiple labels.
LastOne:
Issues only the final page.
In count case, it issues only 1 label while
continuing.
Disabled:
Makes the repeat key invalid.
Interfaces
RS-232C Baud
9600
115200
Sets the baud rate of the serial interface.
57600
• Interface related settings are effective
38400
after the power is turned on again.
19200
9600
4800
2400
RS-232C Parity
None
None
Sets the communication parity of the serial
Odd
interface.
Even
RS-232C Length
8 bits
8 bits
Sets the character length of the serial
7 bits
interface.
RS-232C Stop bit
1 bit
1 bit
Sets the stop bit of the serial interface.
2 bits
RS-232C X-ON
Yes
Yes
Selects the X-ON flow control of the serial
No
interface.
IEEE1284
ON
ON
Enable or disables the 'enhanced' features of
OFF
the IEEE1284 parallel interface.
Mode Settings