16

Vermont Castings Intrepid Multi-Fuel

2000970

ST511a

Intrepid

flue centerline

Diagrams

11/16/00

A

B

C

D

E

F

ST51

Intrepid

flue centerline

Diagrams

11/16/00

*

A

B

C

*

D

E

F

Distance from the Center of the Flue Collar to the Wall in Top-Exit Installations

The information on this page is helpful in planning stove placement for top-exiting installations, particularly those in-
stallations with chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances
must adhere to the guidelines stated in the clearance charts on Page 13.

** To locate center of flue collar for corner installation, add 7” (178 mm) to the clearance distance from stove corner to wall. Mark off the resulting
distance from the corner along both walls. Next, measure the same distance from these two points out from the walls. These last two measure-
ments will meet at a point representing the center of the flue collar. Refer to the diagrams above.

Side (A)

Rear (B)

Corner (C)

Side (D)

Rear (E)

Corner (F)

34³⁄₄”

15”

18³⁄₄”

22³⁄₄”

8”

16³⁄₄”

(883 mm)

(381 mm)

(476 mm)

(578 mm)

(203 mm)

(426 mm)

Parallel Installations

Corner

Installations**

Corner

Installations**

Parallel Installations

Intrepid Mult-fuel: WITH Stove and Chimney Connector Heat Shields

Unprotected Surfaces

Protected Surfaces

ST511a

Side (A)

Rear (B)

Corner (C)

Side (D)

Rear (E)

Corner (F)

34³⁄₄”

29”

26³⁄₄”

22³⁄₄”

11”

16³⁄₄”

(883 mm)

(737 mm)

(680 mm)

(578 mm)

(279 mm)

(426 mm)

Parallel Installations

Corner

Installations**

Corner

Installations**

Parallel Installations

Intrepid Multi-fuel: WITHOUT Stove and Chimney Connector Heat Shields

Unprotected Surfaces

Protected Surfaces

ST511

* This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this page: 35” in the United