VENT-FREE RADIANT FLAME

®

HEATER

SPECIFICATIONS

BTU (Variable)

14,000/28,000

Type Gas

Propane/LP Only

Ignition

Piezo

Pressure Regulator Setting

8" W.C.

Inlet Gas Pressure (in. of water) *

Maximum

14"

Minimum

11"

Dimensions, Inches (H x W x D)**

Heater

23.75 x 25.9 x 8.5

Carton

26 x 27.75 x 10.25

Weight (pounds)

Heater

29

Shipping

35

*For purposes of input adjustment
**Measurement includes knobs and hood

SERVICE HINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burner will have delayed ignition

• heater will not produce specified heat

• propane/LP gas supply may be low

When Gas Quality Is Bad

• pilot will not stay lit

• burner will produce flames and soot

• heater will backfire when lit

You may feel your gas pressure is too low or
gas quality is bad. If so, contact your local
propane/LP gas supplier.

CLEANING AND
MAINTENANCE

ODS/PILOT AND BURNER

• Use a vacuum cleaner, pressurized air,

or small, soft bristled brush to clean.

CABINET

Air Passageways

• Use a vacuum cleaner or pressurized air

to clean.

Exterior

• Use a soft cloth dampened with a mild

soap and water mixture. Wipe the cabi-
net to remove dust.

WARNING: Turn off heater

and let cool before cleaning.

CAUTION: You must keep

control areas, burner, and circu-
lating air passageways of heater
clean. Inspect these areas of
heater before each use. Have
heater inspected yearly by a quali-
fied service person. Heater may
need more frequent cleaning due
to excessive lint from carpeting,
pet hair, etc.

TECHNICAL
SERVICE

You may have further questions about in-
stallation, operation, or troubleshooting.

If so, contact DESA International’s Techni-
cal Service Department at 1-800-323-5190.