Thermostat
Sensing Bulb

Clamp

Figure 11 - Attaching Thermostat Sensing
Bulb

INSTALLATION

Continued

INSTALLATION OPTIONS

There are three options for mounting this
heater.

A. Mounting heater to wall
B. Mounting heater to optional hearth base
C. Mounting heater with optional hearth

base to optional mantel

A. MOUNTING HEATER TO
WALL

Mounting Bracket

The mounting bracket is located on back panel
of heater. It has been taped there for shipping.
Remove mounting bracket from back panel.

Figure 12 - Mounting Bracket Location

Mounting
Bracket

Methods For Attaching
Mounting Bracket To Wall

Only use last hole on each end of mounting
bracket to attach bracket to wall. These two
holes are 16 inches apart from their centers.
Attach mounting bracket to wall in one of
two ways.

1.

Attaching to wall stud

2.

Attaching to wall anchor

Attaching To Wall Stud

This method

provides the strongest hold. Insert mounting
screws through mounting bracket and into
wall studs.

Attaching To Wall Anchor

This method

allows you to attach mounting bracket to
hollow walls (wall areas between studs) or
to solid walls (concrete or masonry).

Decide which method better suits your needs.
Either method will provide a secure hold for
the mounting bracket.

Marking Screw Locations

1.

Tape mounting bracket to wall where
heater will be located. Make sure
mounting bracket is level.

WARNING: Maintain minimum

clearances shown in Figure 13. If
you can, provide greater clear-
ances from floor and joining wall.

2.

Mark screw locations on wall (see Fig-
ure 13).

Note:

Only mark last hole on each end of

mounting bracket. Insert mounting screws
through these holes only.

3.

Remove tape and mounting bracket
from wall.

Figure 13 - Mounting Bracket Clearances

20 3/4"

Min.

11"

Min.

16"

Adjoining Wall

Only Insert Mounting

Screws Through Last

Hole On Each End

Floor

Attaching Mounting Bracket to
Wall

Note:

Wall anchors, mounting screws, and

spacers are in hardware package. The hard-
ware package is provided with heater.

Attaching To Wall Stud Method

For attaching mounting bracket to wall studs.

1.

Drill holes at marked locations using
9/64" drill bit.

2.

Place mounting bracket onto wall. Line
up last hole on each end of bracket with
holes drilled in wall.

3.

Insert mounting screws through bracket
and into wall studs.

4.

Tighten screws until mounting bracket
is firmly fastened to wall studs.

THERMOSTAT SENSING
BULB

The thermostat sensing bulb has been
placed inside the heater for protection
during shipping.

Locating Thermostat Sensing
Bulb

1.

Remove front panel of heater (see Fig-
ure 2, page 4).

2.

Locate thermostat sensing bulb just
under burner assembly.

IMPORTANT:

Attach thermostat sensing

bulb to back of heater for proper operation.

Attaching Thermostat Sensing
Bulb

1.

Remove thermostat sensing bulb from
holders inside heater. Route through
slot opening in bottom of heater.

2.

Place clamp on thermostat sensing bulb
as shown in Figure 11. Clamp is pro-
vided in hardware package.

3.

Snap clamp into upper mounting hole
as shown in Figure 11. Mounting hole
is located on lower left edge on back
of heater. Make sure the thermostat
sensing bulb is pointing up.