beautypg.com

Vent-free radiant flame, Heater, Installation – Desa Tech RFP28TC User Manual

Page 14: Continued

background image

14

103509

VENT-FREE RADIANT FLAME

®

HEATER

CHECKING GAS
CONNECTIONS

Pressure Testing Gas Supply
Piping System

Test Pressures In Excess Of 1/2 PSIG

1.

Disconnect heater and its individual
manual shutoff valve from gas supply
piping system. Pressures in excess of
1/2 psig will damage heater regulator.

2.

Cap off open end of gas pipe where
manual shutoff valve was connected.

3.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

4.

Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

6.

Reconnect heater and manual shutoff
valve to gas supply. Check reconnected
fittings for leaks.

WARNING: Test all gas pip-

ing and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.

WARNING: Never use an open

flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. Bubbles forming show
a leak. Correct all leaks at once.

CAUTION: Make sure exter-

nal regulator has been installed
between propane/LP supply and
heater. See guidelines under

Con-

necting to Gas Supply, page 13.

O

POSI

PO

Open

Closed

Manual
Shutoff
Valve

Figure 23 - Checking Gas Joints

Manual
Shutoff
Valve

Propane/LP
Supply Tank

Figure 22 - Manual Shutoff Valve

Thermostat Gas
Valve Location

INSTALLATION

Continued

Test Pressures Equal To or Less Than
1/2 PSIG

1.

Close manual shutoff valve (see Fig-
ure 22).

2.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

3.

Check all joints from propane/LP sup-
ply tank to manual shutoff valve (see
Figure 23). Apply mixture of liquid
soap and water to gas joints. Bubbles
forming show a leak.

4.

Correct all leaks at once.

Pressure Testing Heater Gas
Connections

1.

Open manual shutoff valve (see Fig-
ure 22).

2.

Open propane/LP supply tank valve.

3.

Make sure control knob of heater is in
the OFF position.

4.

Check all joints from manual shutoff
valve to thermostat gas valve (see Fig-
ure 23). Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

6.

Light heater (see Operating Heater,
pages 15 and 16). Check all other in-
ternal joints for leaks.

7.

Turn off heater (see To Turn Off Gas to
Appliance
, page 15).

8.

Replace front panel.