Using the Wall-Mounted Door Control
THE MOTION DETECTING CONTROL CONSOLE
Press the push bar to open or
close the door. Press again to
reverse the door during the
closing cycle or to stop the door
while it's opening.
This door control contains a
motion detector that will
automatically turn on the light
when it detects a person entering
the garage. This feature can be easily turned off for
extended work light use.
Light Feature
Press the Light button to turn the opener light on or
off. It will not control the opener lights when the door is
in motion. If you turn it on and then activate the
opener, the light will remain on for 4-1/2 minutes.
Press again to turn it off sooner. The 4-1/2 minute
interval can be changed to 1-1/2, 2-1/2, or 3-1/2
minutes as follows: Press and hold the Lock button
until the light blinks (about 10 seconds). A single blink
indicates that the timer is reset to 1-1/2 minutes.
Repeat the procedure and the light will blink twice,
resetting the timer to 2-1/2 minutes. Repeat again for a
3-1/2 minute interval, etc., up to a maximum of four
blinks and 4-1/2 minutes.
When using the opener lights as working lights, we
recommend that you first disable the motion sensor.
See Automatic Light Feature, below.
Automatic Light Feature: The opener light will turn
on automatically when a person enters the garage.
When a person walks in front of the door control, the
light will come on for five minutes, then shut off. This
feature works by detecting body heat and may not
work in temperatures around 100˚F.
To disable this feature, slide the Detector Switch on
the right side of the door control down (off).
We recommend that you disable the motion sensor
when using the opener lights as working lights.
Otherwise, they will turn off automatically if you are
working beyond the sensors range.
Lock Feature
Designed to prevent operation of the door from hand-
held remote controls. However, the door will open and
close from the Door Control, the Outside Keylock and
the Keyless Entry Accessories.
To activate, press and hold the Lock button for 2
seconds. The push bar light will flash as long as the
Lock feature is on.
To turn off, press and hold the Lock button again for
2 seconds.The push bar light will stop flashing. The
Lock feature will also turn off whenever the “Smart”
(learn) button on the motor unit panel is activated.
32
Additional feature when used with the 3-function
hand-held remote
To control the opener lights:
In addition to operating the door, you
may program the remote to operate
the lights.
1. With the door closed, press and hold a small
remote button that you want to control the light.
2. Press and hold the Light button on the
door control.
3. While holding the Light button, press and hold the
Lock button on the door control.
4. After the opener lights flash, release all buttons.
To Open the Door Manually
DISCONNECT THE TROLLEY:
The door should be fully
closed if possible. Pull down
on the emergency release
handle (so that the trolley
release arm snaps into a
vertical position) and lift the
door manually. The lockout
feature prevents the trolley
from reconnecting
automatically, and the door
can be raised and lowered
manually as often as
necessary.
TO RE-CONNECT THE
TROLLEY:
Pull the emergency release
handle toward the opener at
a 45° degree angle so that
the trolley release arm is
horizontal. The trolley will
reconnect on the next UP or
DOWN operation, either
manually or by using the
door control or remote.
• To prevent possible SERIOUS INJURY or DEATH from
a falling garage door:
– If possible, use emergency release handle to
disengage trolley ONLY when garage door is
CLOSED. Weak or broken springs or unbalanced
door could result in an open door falling rapidly
and/or unexpectedly.
– NEVER use emergency release handle unless garage
doorway is clear of persons and obstructions.
• NEVER use handle to pull door open or closed. If rope
knot becomes untied, you could fall.
Lockout position
(Manual disconnect)
NOT
ICE
Trolley
Release arm
(In Manual
Disconnect
Position)
Trolley
To reconnect
NOTICE
Emergency
Release Handle
(Pull at 45
° angle)
Trolley
Release
Arm
Trolley
WARNING
CAUTION
WARNING
WARNING
Push
Bar
Light
Button
Lock
Button
LOCK