INSTALLATION STEP 6

Install the Door Control

Locate door control within sight of door, at a
minimum height of 5 feet (1.5 m) where small
children cannot reach, away from moving parts of
door and door hardware. If installing into drywall, drill
5/32" holes and use the anchors provided. For pre-
wired installations (as in new home construction), it
may be mounted to a single gang box (Figure 2).

1. Strip 7/16" (11 mm) of insulation from one end of

bell wire and connect to the two screw terminals
on back of door control by color: white wire to
2 and white/red wire to the 1.

2. Remove white cover by gently prying at slot in top

of the cover with a small flat head screwdriver.
Fasten with 6ABx1-1/4"self-tapping screws
(drywall installation) or 6-32x1" machine screws
(into gang box) as follows:

• Install bottom screw, allowing 1/8" (3 mm) to

protrude above wall surface.

• Position bottom of door control on screw head

and slide down to secure. Adjust screw
for snug fit.

• Drill and install top screw with care to avoid

cracking plastic housing. Do not over tighten.

• Insert top tabs and snap on cover.

3. (For standard installation only) Run bell wire up

wall and across ceiling to motor unit. Use
insulated staples to secure wire in several places.
Do not pierce wire with a staple, creating a short
or open circuit.

4. Strip 7/16" (11 mm) of insulation from end of bell

wire. Connect bell wire to the quick-connect
terminals as follows: white to white and white/red
to red.

NOTE: When connecting multiple door controls to
the opener, twist same color wires together. Insert
wires into quick-connect holes: white to white and
red/white to red.

5. Position the antenna wire as shown.

6. Use tacks or staples to permanently attach

entrapment warning label to wall near door
control, and manual release/safety reverse test
label in a prominent location on inside of garage
door.

NOTE: DO NOT connect power and operate
opener at this time. The trolley will travel to the
full open position but will not return to the close
position until the sensor beam is connected and
properly aligned.

To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door

control.

• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of

reach of children at a minimum height of 5 feet
(1.52 m), and away from all moving parts of door.

• NEVER permit children to operate or play with door

control push buttons or remote control transmitters.

• Activate door ONLY when it can be seen clearly, is

properly adjusted, and there are no obstructions to door
travel.

• ALWAYS keep garage door in sight until completely

closed. NEVER permit anyone to cross path of closing
garage door.

WARNING

CAUTION

WARNING

WARNING

Dry Wall Anchors

Insulated
Staples

Screw 6AB x 1-1/4"
Control Console (std installation)

Screw 6-32 x 1"
Control Console (pre-wired)

HARDWARE SHOWN ACTUAL SIZE

Outside Keylock Accessory Connections

To opener quick-connect terminals: white to white;
white/red to red.

LOCK

LIGHT

To Replace,
Insert Top
Tabs First

PRE-WIRED
INSTALLATION

REMOVE & REPLACE COVER

Figure 1

Figure 2

24 Volt
2-Conductor
Bell Wire in
Gang Box

LOCK

LIGHT

Lock

Light

2-Conductor
Bell Wire

Terminal
Screws

(BACK VIEW)

Top
Mounting
Hole

Bottom
Mounting
Hole

WHITE

2

RED

1

Bell
Wire

KG

1

3

9

7

5

KG

1

3

9

7

5

Quick-Connect
Terminals

7/16"

Door Control
Connections

To release wire, push in tab
with screwdriver tip

Antenna

Red

Grey

White

Push Bar

LOCK

LIGHT

Strip wire 7/16"
(11 mm)