Save these instructions, S ave these instructions, Maintenance (continued) – Intex CS7111 Krystal Clear Saltwater System 2014 User Manual
Page 21

SAVE THESE INSTRUCTIONS
Page 2
(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013
English
189
PO
S AVE THESE INSTRUCTIONS
English
Page 21
MAINTENANCE (continued)
1. Switch off the unit, unplug the power cord from the electrical socket.
2. Turn both plunger valve handles fully clockwise until they stop. This closes the valve,
prevents the water from flowing out of the pool.
3. Disconnect the hose with nut (8) from the Saltwater System, and assemble the cell cover (30)
at the side of the cell.
4. In a counter-clockwise motion, unscrew the collar of the copper electrode (14) and remove it
from the electrolytic cell. Lift up the copper electrode.
5. Pour kitchen grade vinegar into the cell to immerse the titanium plates. Then put the copper
electrode back in the cell, soak them for about one hour until no colored areas remain.
6. Open one side of the cell cover (30), drain and properly dispose of the vinegar. Connect the
hose which goes from the pool to the cell. Flush the cell with the pool water.
7. Reverse steps 3, 4, 5 and 6 to reconnect the electrolytic cell.
30
8