beautypg.com

Save these instructions, S ave these instructions, Important – Intex CS7111 Krystal Clear Saltwater System 2014 User Manual

Page 10: Saltwater system/filter pump

background image

SAVE THESE INSTRUCTIONS

Page 2

(189PO) MODEL CS7111 SALTWATER SYSTEM & FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/28/2013

English

189

PO

S AVE THESE INSTRUCTIONS

English

Page 10

SALTWATER SYSTEM/FILTER PUMP

Saltwater System/Filter Pump

1. Remove the Saltwater System/Filter Pump and hoses from the packaging.

2. Place the Saltwater System/Filter Pump in a location for hose (8) connections to the plunger

valve assemblies.

NOTE: Some regional regulations may require the filter pump to be mounted on a

stationary platform. There are two mounting holes located in the pump base for this

reason. Consult your local authorities for filter pump mounting requirements.

3. Grasp the two pump hoses (8) and connect the hose nuts to the Saltwater System/Filter

Pump.

4. In a counter-clockwise motion unscrew the threaded filter housing collar (3) from the filter

housing. Place it in a safe place.

5. The Saltwater System/Filter Pump is an airtight system. In a counter-clockwise motion turn

both air release valves

(1 & 7) 1 - 2 turns to open. DO NOT remove air release valves as

water will expel with force if the motor is turned on and injury may occur.

6. Grasp and remove the filter housing cover (4). Check to see if a cartridge is inside the

housing. If yes, replace the cover, finger tighten the housing collar

(3) back onto the filter

housing.

7. Gently finger tighten the sediment release valve located at the bottom of the housing to be

sure that water does not leak out.

8. When the pool is filled connect the hose from the electrolytic cell outlet to the highest strainer

assembly.

You will find the hose connection at the bottom of the plunger valve assembly. Use

the hose nut to attach the hose.

9. Connect the second hose to the middle of the motor housing and to the remaining liner

connection.

IMPORTANT

To prevent air lock, open the lower plunger valve (connected inlet hose) first and

then the upper plunger valve (connected outlet hose). Open air release valves, lift

and lower the inlet hose until water starts to flow out of the air release valves, close

air release valves.