Unit Environment and
Operating Conditions

Ultra-slim Desktop

Small Form Factor

Convertible Minitower

General Unit Operating Guidelines

Keep the computer away from excessive moisture, direct moisture and the extremes of heat and cold, to ensure that
unit is operated within the specified operating range.
Leave a 10.2 cm (4 in) clearance on all vented sides of the computer to permit the required airflow.
Never restrict airflow into the computer by blocking any vents or air intakes.
Do not stack computers on top of each other or place computers so near each other that they are subject to each
other's re-circulated or preheated air.
Occasionally clean the air vents on the front, back, and any other vented side of the computer. Lint, dust and other
foreign matter can block the vents and limit the airflow.
If the computer is to be operated within a separate enclosure, intake and exhaust ventilation must be provided on the
enclosure, and the same operating guidelines listed above will still apply.

Temperature Range

Operating: 50° to 95° F (10° to 35° C)*

Non-operating: -22° to 140° F(-30° to 60° C)

Relative Humidity

Operating: 10% to 90% (non-condensing at ambient)

Non-operating: 5% to 95% (non-condensing at ambient)

Maximum Altitude
(unpressurized)

Operating: 10,000 ft (3048 m)

Non-operating: 30,000 ft (9144 m)

* Operating temperature is de-rated 1.0 deg C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level, no direct sustained
sunlight. Maximum rate of change is 10 deg C/Hr. The upper limit may be limited by the type and number of options
installed.

Power Supply

Ultra-slim Desktop

Small Form Factor

Convertible Minitower

Power Supply

135 watt External custom power

supply – Active PFC)

240 watt custom power supply –

Active PFC

365 watt custom power supply –

Active PFC)

Operating Voltage Range

90 – 264 VAC

90 – 264 VAC

90 – 264 VAC

Rated Voltage Range

100 – 240 VAC

100 – 240 VAC

100 – 240 VAC

Rated Line Frequency

50/60 Hz

50/60 Hz

50/60 Hz

Operating Line
Frequency Range

47 – 63 Hz

47 – 63 Hz

47 – 63 Hz

Rated Input Current

N/A

4A

6A

Rated Input Current with
80% Efficient* Power
Supply

1.5A

3.5A

5A

Current Leakage
(NFPA 99)

< 275 µA

< 275 µA

< 450 µA

System Heat Dissipation

N/A

Typical 198 btu/hr

(50 kg-cal/hr)

Maximum 1260 btu/hr

(318 kg-cal/hr

Typical 222 btu/hr

(56 kg-cal/hr)

Maximum 1916 btu/hr

(483 kg-cal/hr)

System Heat Dissipation
with 80% Efficient* Power
Supply

Typical 133 btu/hr

(33.5 kg-cal/hr)

Maximum 549 btu/hr

(132 kg-cal/hr)

Typical 150 btu/hr

(38 kg-cal/hr)

Maximum 1024 btu/hr

(258 kg-cal/hr)

Typical 171 btu/hr

(43 kg-cal/hr)

Maximum 1557 btu/hr

(392 kg-cal/hr)

Power Supply Fan

N/A

80mm variable speed

92mm variable speed

ENERGY STAR
Compliant
with 80% Efficient* Power
Supply

X

X

X

QuickSpecs

HP Compaq dc7800 Business PC

Technical Specifications

DA - 12744 Worldwide QuickSpecs — Version 13 — 12.14.2007

Page 19