21 Sp

4

Operation

(Continued)

continuously, the compressor will cycle
on and off automatically.

In the OFF position, the pressure switch
cannot function and the compressor
will not operate. Make sure switch is in
OFF position when connecting or
disconnecting power cord from
electrical outlet.

ASME SAFETY VALVE

Do not

remove or

attempt to adjust the safety valve!

Check the safety valve by performing
the following steps:
1. Plug the compressor in and run until

shut off pressure is reached (see
Operating Procedure).

2. Wearing safety glasses, pull the ring

on the safety valve to release
pressure from compressor tank. Use
your other hand to deflect fast-
moving air from being directed
toward your face.

3. The safety valve should

automatically close at approximately
40-50 psi. If the safety valve does not
allow air to be released when you
pull on the ring, or if it does not
close automatically, it MUST be
replaced.

Maintenance

Disconnect power source
then release all pressure
from the system before
attempting to install, service, relocate
or perform any maintenance.

Check compressor often for any visible
problems and follow maintenance
procedures each time compressor is used.

Safety

valve

must be replaced if it cannot be
actuated or it leaks air after ring is
released.

1. Turn compressor off and release

pressure from system. (To release
pressure from system, pull ring on
ASME safety valve. Deflect escaping
air by shielding valve with one hand
as you pull ring with other hand.)
Pull ring until tank is empty.

A large

amount of

fast moving air will be released when
the safety valve is opened with
pressure in the tank. Wear ANSI
approved Z87.1 safety glasses.

2. Drain moisture from tank by opening

drain valve underneath tank. Tilt
tank to remove all moisture.

3. Clean dust and dirt from tank, air

lines and pump cover while
compressor is still OFF.

LUBRICATION

This is an oilless type compressor
requiring no lubrication.

THERMAL OVERLOAD PROTECTOR

This

compressor is equipped with an
automatic reset thermal overload
protector which will shut off motor if it
becomes overheated.

If thermal overload protector shuts
motor OFF frequently, make sure that
the compressor is used in a clean, well-
ventilated area where temperature will
not exceed 100° F.

If the
thermal

overload protector is actuated, the
motor must be allowed to cool down
before start-up is possible. The motor
will automatically restart without
warning if left plugged into electrical
outlet and unit is turned on.

STORAGE

1. Drain tank of moisture.

Drain

moisture

from tank daily. Failure to drain tank
can result in weakening due to rust and
bursting.

2. When not in use, store compressor in

a cool dry place.

3. Disconnect hose and hang open ends

down to allow any moisture to drain.

MOISTURE IN COMPRESSED AIR

Moisture in compressed air will form into droplets as it comes from an air
compressor pump. When humidity is high or when a compressor is in continuous
use for an extended period of time, this moisture will collect in the tank. When
using a paint spray or sandblast gun, this water will be carried from the tank
through the hose, and out of the gun as droplets mixed with the spray material.

IMPORTANT: This condensation will cause water spots in a paint job, especially
when spraying other than water based paints. If sandblasting, it will cause the
sand to cake and clog the gun, rendering it ineffective. A filter in the air line
(MP3105), located as near to the gun as possible, will help eliminate this
moisture.

Oilless Compressors

Guía de diagnóstico de averías

Problema

Posible(s) Causa(s)

Acción a tomar

1. El interruptor está en la posición OFF

(apagado)

2. No hay corriente eléctrica en el

tomacorriente de la pared

3. El compresor alcanzó la presión de

corte automático

4. Motor recalentado

5. Interruptor de presión defectuoso

1. Falta de ventilación adecuada/

temperatura ambiente demasiado
alta

2. Fallaron las válvulas del compresor

1. El tanque no está nivelado
2. Cojinete defectuoso en la excéntrica o

en el eje del motor

3. El aro del cilindro o pistón está

desgastado o marcado

1. Válvula de drenaje floja
2. Fugas en la válvula de retención
3. Conexiones flojas (accesorios, tubería,

etc.)

1. Uso excesivo de aire, el compresor es

demasiado pequeño

2. Conexiones flojas (accesorios, tubería,

etc.)

3. Válvulas de entrada averiadas
4. Aro del pistón desgastado

1. Asegúrese de que el compresor esté enchufado y que

el interruptor esté en la posición ON (encendido)

2. Revise el disyuntor o fusible en el panel de

electricidad.

3. Libere aire del tanque hasta que el compresor se

reinicie automáticamente.

4. Deje que el compresor se enfríe durante

aproximadamente 30 minutos para que el interruptor
térmico de sobrecarga vuelva a su posición normal.
Asegúrese de que el compresor esté funcionando en
un área limpia y bien ventilada donde la temperatura
no exceda los 38ºC.

5. Cambie el interruptor de presión

1. Mueva el compresor a un área limpia y bien ventilada

donde la temperatura no exceda los 38ºC.

2. Cambie el ensamblaje de la bomba

1. Nivele el tanque

2. Cambie el ensamblaje de la bomba

3. Cambie el ensamblaje de la bomba

1. Apriete la válvula de drenaje

2. Cambie la válvula de retención
3. Revise todas las conexiones con una solución de agua

y jabón. Si se detecta una fuga, apriete. O quite la
conexión y aplique cinta para tuberías a las rocas y
vuelva a armar.

No desarme la válvula

de retención. Si hay

aire en el tanque, primero purgue el tanque.

1. Disminuya el uso o compre una unidad que ofrezca

una entrega de aire mayor (SCFM)

2. Revise todas las conexiones con una solución de agua

y jabón. Si se detecta una fuga, apriete. O quite la
conexión y aplique cinta para tuberías a las rocas y
vuelva a armar.

3. Cambie el ensamblaje de la bomba
4. Cambie el ensamblaje del pistón

El compresor no
funciona

El protector térmico de
sobrecarga detiene el
funcionamiento
reiteradamente

Golpeteos, zumbidos,
vibración excesiva.

La presión del tanque
disminuye cuando se
apaga el compresor

El compresor funciona
en forma continua y la
salida de aire es más
baja que la presión de
descarga normal/baja.

FP202800, FP202900, FP202897, FP202999DB,

FP202999DQ, y FP202899TT

This manual is related to the following products: