beautypg.com

Using the sub-unit, Using the weather forecast feature, Main unit/sub unit communication precautions – Casio DQR-300U User Manual

Page 6: Radio, emc and safety regulations, Operation guide dqr-300u

background image

Operation Guide DQR-300U

6

• To clear the high humidity and low humidity data memory, press the

CLEAR button

(9).

New data starts to be stored after memory is cleared.

USING THE SUB-UNIT

Data Transfer from the Sub-unit

• Data is transferred from the sub-unit to the main unit every three minutes.

• The sub-unit is able to send data to the main unit up to an unobstructed distance of about 30 meters.

• The data receive status is indicated on the display of the main unit by the icons shown below.

Receive successful

Receive unsuccessful

• If a receive operation is not successful for some reason, the display of the main unit shows dashes (–) in place of

the sub-unit temperature and humidity values.

• If you experrience problems with data transfer, press the

RE-SYNC button

(A) to synchronize the two units.If

this does not eliminate the problem,try changing the positions or orientations of the main unit and sub-unit.

• The transferred data includes temperature and humidity data.

Switching between Celsius and Fahrenheit

• Push the °

C/

°

F button

(F) to toggle between Celsius (

°C) and Fahrenheit (°F).

Celsius (

°

C)

Fahrenheit (

°

F)

°

C/

°

F button

(F)

Switching between Current Temperature and Humidity

• Press the

SELECT button

(C) to toggle the display between the current temperature and current humidity.

• Holding down

SELECT button

(C) for about two seconds causes the display to continually toggle between the

temperature and humidity at five-second intervals.

Temperature

Humidity

SELECT button

(C)

Location

• Place the sub-unit in a location where it will not be exposed to rain, direct sunlight, or other elements.

CLEAR button (

9

)

USING THE WEATHER FORECAST FEATURE

A built in pressure sensor makes it possible to forecast upcoming weather over the next 12 hours based on
changes in barometric pressure. Note that these forecasts are not absolutely accurate, and are intended for
general reference only.

Weather Forecasts

• Barometric pressure readings are taken every 15 minutes. Weather forecasts are based on the last six readings.

Upcoming weather forecasts are displayed using the graphic indicators shown below.

Sunny

Sunny, some clouds

Cloudy

Rain

Stormy

• Upcoming weather trends are indicated as shown below.

Improving weather

Deteriorating weather

Stable weather

MAIN UNIT/SUB UNIT COMMUNICATION PRECAUTIONS

Sub Unit Location

• Certain environmental conditions can greatly reduce the communication range.

• Avoid the following locations for the sub-unit.

Inside, among
buildings, or near
neon signs

Inside a vehicle

Near refrigerators
or other household
appliances, near
office equipment,
mobile phones or
wireless LAN
devices.

Near a
construction site,
airport, or other
sources of
electrical noise,
underground or in
tunnels, near
railroads,
highways, or radio
stations with
interfering
frequencies.

Near high-tension
power lines

• Locating the sub-unit near a device that transmits radio signals using the same frequency as this product can

cause communication failure of this product.

• Avoid using multiple products in the same area. Doing so can cause mixing of their signals.

RADIO, EMC AND SAFETY REGULATIONS

This product complies with technical specifications required under EN 301 489-3,EN 300-220-3 and EN 60950.