beautypg.com

Mounting and wiring the detector, Selecting the coverage pattern – Interlogix AP950PI User Manual

Page 2

background image

Do not locate the unit where the ambient temperature is

below 0° F (-18°C) or above 122°F (50°C).

Do not aim the unit at windows or glass doors.

Caution:

You must be free of static electricity before handling

sensor circuit boards. Touch a grounded, bare metal surface

before touching circuit boards or wear a grounding strap.

Mounting and wiring the detector

1. Separate the front housing from the back housing by

pressing in on the opening tab at the bottom of the unit

with a small, flat bladed screwdriver. See Figure 3 below.

2. Select and remove the appropriate corner or flat wall

mounting knockouts and the cable entry knockout on the

back housing. See Figure 1 on page 1.

3. Strip the cable 2 inches (5cm) and pull it through the cable

entry knockout. Use screws and wall anchors, if

necessary, to attach the back housing to the wall. Do not

overtighten.

4. Select the appropriate coverage pattern. See “Selecting

the coverage pattern” below

Figure 3: Front housing interior

Jumpers:
SENS MODE LED

Cable strain relief

Terminal block

GND +12V NC COM

Mirror snaps

Mirror

Opening tab

Wires

5. Set the sensitivity, mode, and LED jumpers for the

application desired. See “Setting the sensitivity, mode, and

LED jumperson page 3.

6. Strip 1/4 inch (0.6cm) of insulation from each wire.

7. Insert each wire into the appropriate terminal and tighten

screws. Push the wires into the strain relief. See Figure 3

above.

8. To close the unit, insert the hinge tabs at the top of the

front housing into the slots at the top of the back housing

then swivel the front housing toward the back housing to

snap the unit closed. See Figure 1 on page 1.

9. Fasten the housings together with the screw provided.

Selecting the coverage pattern

The coverage pattern for the unit can be modified to fit specific

applications by masking off mirror curtains. Curtains should be

masked to avoid sources of false alarms, such as heaters, air

conditioners, and windows.

Remove the mirror by inserting a small screwdriver between

the mirror and the side of the front housing and gently prying

the mirror out. Do not pry from the end of the housing because

the mirror may be scratched. See Figure 3 above.

Figure 4: Plastic masks

2

1

2

1

Figure 5: Adhesive labels

A

B

9

1

A

B

1

2

3

4

5

6

7

8

2

3

4

5

6

7

8

9

9

8

7

6

5

4

3

2

1

Figure 6: Cardboard undercrawl window mask

5.0 ft
(1.5m)

7.9 ft

(2.4m)

2

AP950PI PIR Detector Installation Instructions