Interlogix NX-8E User Manual User Manual
Page 15

13
Step 2
Each time a zone is faulted, the zone light on the LED keypad will
illuminate and the chime will sound. The number of the faulted
zone(s) will be displayed on the LCD keypad. It will also be entered
into alarm memory and the internal log.
Step 3
The keypad will begin to beep after 15 minutes in this mode. This
beeping indicates that the “Walk-Test” mode will be automatically
exited in 5 minutes.
Step 4
To exit at any time during this mode, enter a user code. Otherwise
the Walk-Test Mode@ will automatically exit after 20 minutes.
RESET FUNCTION
This function is used to reset Smoke Detectors, Zone Troubles, and Zone
Tampers.
Step 1
Disarm the system if not disarmed.
Step 2 Press [
]-[7]. Resets have now been performed.
Step 3
If the keypad begins beeping, the reset did not execute properly.
Enter your code to silence the keypad. Wait a few minutes and
repeat step 2 to attempt another reset. If the keypad still beeps after
repeated attempts, please contact your installer.
SET SYSTEM DATE
Step 1
Press the [
]-[9]-[6].
Step 2
Enter the “Master Code”.
Step 3
Enter the “Day of Week “
1 = Sunday
3 = Tuesday
5 = Thursday
7 = Saturday
2 = Monday
4 = Wednesday
6 = Friday
Step 4
Enter the “Month Code”. Must always be two (2) digits.
01 = January
05 = May
09 = September
02 = February
06 = June
10 = October
03 = March
07 = July
11 = November
04 = April
08 = August
12 = December
Step 5
Enter the “Day Code”. Must always be two (2) digits.
Example: The 5
th
would be entered as [0]–[5].
Step 6
Enter the last two digits of the “Year Code”.
Example: For 1997 enter [9]–[7].
SETTING THE SYSTEM CLOCK
Step 1
Press [
]-[9]-[7].
Step 2
Enter the “Master Code “.
Step 3
Enter the “hour code” which must be two (2) digits. Note: The clock
is a 24-hour clock. Refer to the following table on page 15.