Intellijel Plog 1.0 User Manual
Page 2
Plog rev 1.0 MANUAL
2
1 - TYPE (LOAD)
This button selects the logic type for the
selected channel, A or B. It also acts as
the starting point when under CV con-
trol. Press and hold this button for one
second to load the stored preset from
memory.
2 - These two mini knobs attenuate the
CV coming into their respective CV in-
puts labeled Type A and Type B.
3 - Type A/B bipolar CV input for logic
type of channel A/B. You will see the
logic type LEDs move when CV is pres-
ent and SELECT is on A/B.
4 - X Input X for logic operator
5 - Y Input Y for logic operator
6 - Z Input Z for logic operator.
This is a switching jack with Input Y nor-
malled to it unless patched.
The X and Y inputs for Logic block A are
normalled to the X and Y inputs of B.
7- OUT A /B is the output of the logic
operation.
8 - SELECT (SAVE)
Pressing this button selects between
logic A or B for the display of the yellow
Front Panel
LED logic type and the operation of the TYPE button. Pressing and holding this button for more than
one second will save the logic type selections into non-volatile memory.
9- TRIGGER button is normalled to the TOGGLE input below. When pressed it will send a trigger
to the toggle flip flop. Press and hold on this button for one second and it will become a simple tap
tempo clk generator. Once in TAP MODE, start clicking the button in time with the tempo you would
like to set. To return to T-Flip-Flop mode simply hold the same button again for 1 second.