Harness Overview

The Haltech 2JZ Terminated Engine Harness is a plug and play solution for wiring a
Toyota 2JZ-GTE Engine.

Installation is simple and easy as the harness is designed for the engine, all lengths
are correct and all wires are clearly labeled.

Notes on installation:

Make sure your Engine is grounded.
A Ground / earthing strap should be used to ground your engine to the chassis of the
vehicle. The Haltech Terminated Engine harness does not ground your engine.
Damage can occur to your harness and / or ECU if you do not ground your engine
properly.

The Harness is designed to be used with the Rear Cam Sensor,
Please use the rear Cam sensor when connecting the harness

Factory starting and charging circuits are to be used the harness does not incorporate
connections for the starting or charging of the vehicle.

Keep all wires away from the Exhaust manifold.

Haltech HPI Ignition Harness Overview

The Haltech 2JZ Terminated Engine Harness incorporates the use of a
Haltech High Power Igniter unit for the ignition.

The Haltech HPI 6 Ignition Harness connects to the standard coils of the engine

Installation of this harness is as follows:

Position the harness in the engine bay / cabin

Connect the Haltech HPI 6 Ignition Harness to the
Haltech 2JZ Terminated Engine Harness by the opposing 8 position
deutsch connectors within the harness labeled as “Ignition Outputs”

Connect the factory coils to the ignition harness all outputs are labeled on the
harness please connect to their respective cylinder / coil

Connect the HPI 6 unit to the harness via the main connector within the
Haltech HPI 6 Ignition Harness

Mount the HPI 6 Unit on the vehicle, do not mount the unit where it will be
exposed to water or other liquids. Select a location away from excessive
heat.

Connect the Main Power Ground to a clean chassis ground

Please Refer to the included HPI 6 Quick Start Guide for more information

Figure 9 – Haltech HPI 6 Ignition Harness Main Power Connection